Multi-Channel Recorders
- Capacity to store up to 300,000 interval computations in memory
- Accept analog or event inputs with sample rates from one per second up to one every eight hours
- Combine these units with a power source and communication option
- Administer a network of hundreds of remote recorders throughout your municipality or across your client base
The Telog R-33xx recorders become your eyes and ears in the field. The recorders accept analog and/or event inputs with a sample rate of 1 per sec up to 1 per 8 hours, storing up to 300,000 interval computations in memory. Telog R-33xx units record output from a variety of sensors such as pressure, level, flow, pH, temperature and humidity. Combine the Telog R-33xx recorders with a power source and communication option to easily administer a network of hundreds of remote recorders.
Alarm notification for critical point monitoring is available. Each alarm event is time-stamped and stored in the recorder's wrap around memory. Backup battery packs ensure data integrity in the event of a power source failure.
Telog's R-33xx family of multi-channel remote recorders provide you with cost effective tools for gathering, understanding and managing information from your system. Designed for multiple applications, the Telog R-33xx recorders can work in a network or as solo data loggers, indoors or outdoors, battery-operated or externally powered. Support software copies the stored data for detailed analysis and professional presentations.

Applications:
- CSO/SSO monitoring and alarm notification
- Pump station run-time monitoring
- I & I studies
- Potable water distribution monitoring
- Rain fall monitoring
- Tank level monitoring
- Lake level monitoring
Get Telog Multi-Channel Recorder
BENEFITS
NEMA 4x Enclosure and IP67 Rated
All connectors and fittings are watertight and the product is environmentally rated IP67 to 3 meters of depth
Battery Operated
AC power is not needed, significantly reducing installation and maintenance costs
Cellular
Provided with the Telog WM2/L1 cellular modem LTE Category 1 certified Verizon Wireless and upgradeable to future communications technologies
Data Backup
Data loss is not a concern because the recorder stores over 67,000 interval statistics before overwriting the oldest data with new
articles
Cellular data transfer is the ticket for successful pump station monitoring in Suffolk
Monitoring Progress: Nailing Down Water Hammer And Its Implications
White Papers
Automated Wireless Monitoring of Water Distribution Systems
SCADA Alternatives for Remote Monitoring
Recorder Model: Telog R-3303
Type: Multi-channel RTU (recording telemetry unit)
Recorder Channels
-- 3 Pulse/event channels
Memory
-- Dynamically allocated among active channels: 256 Kbytes
--- Pulse inputs: 82,500 16-bit values
--- Event input: 27,500 events
--- Storage: Wrap-around (first-in, first-out, FIFO) memory
Pulse/event Inputs:
-- Type: Pulse counting or event recording, user selectable
-- Input: Uncommitted contact or active logic signals
-- Excitation: 10 µA contact sensing current; 5 volt pull-up
-- Contact bounce: 3 ms maximum, software programmable bounce filter
Pulse Totalizing:
-- Pulse rate: Low speed 100/s with bounce filter; Maximum pulses: 65,000 per interval; High speed: 20,000/s with no bounce filter
-- Totalizing interval: 1 s to 8 h, synchronized to the hour, channel independent
-- Values saved: Totals, overall and per interval
Event Sampling
-- Event rate: 1 event/s maximum
Alarms
-- Activation: Event inputs only
-- Outputs: 2 Discrete outputs
-- Type: FET, open collector (open drain)
-- Maximum specifications: 30 VDC & 100 mA
-- Threshold: Event activated
Power
-- Battery type: 9-volt lithium battery pack with MTA connector
-- Battery life: 8 months @ 73.4º F, with 1 sample every 5 s on all channels, no modem
-- External DC: Regulated 12 VDC; Unregulated 15-35 VDC
Communication
-- Local RS-232 (standard); Opto-isolated; 300 to 19,200 baud via 9 pin D connector
-- Cellular: Internal Telog WM2/L1 cellular modem LTE Category 1 certified Verizon Wireless
-- Modem upgradable to future communications technologies
Mechanical & Environmental
-- Clock accuracy: ±0.01%
-- Operating temperature: -4 to 140º F
-- Enclosure: Bent aluminum panel mount assembly; size: 8.5"x6.8"x2.3"
-- Options: Fiberglass, IEC IP65 NEMA 4X enclosures
Support Software
-- Telog Online (Data Hosted Solution)
-- Telog Enterprise
-- Telogers for Windows
-- Trimble Unity
Recorder Model: Telog R-3307
Type: Multi-channel RTU (recording telemetry unit)
Recorder Channels
-- 3 Pulse/event channels
-- 4 Analog
Memory
-- Dynamically allocated among active channels: 256 Kbytes
--- Analog inputs only: 110,000 12-bit values
--- Pulse inputs only: 82,500 16-bit values
--- Event inputs only: 27,500 events
--- Storage: Wrap-around (first-in, first-out, FIFO) memory
Analog Inputs:
-- Type: Selectable using software
--- Voltage: Bipolar or unipolar 100 mV, 200 mV, 500 mV, 1, 2, 5, 10, or 20 V full scale, or unipolar 1 to 5 V
--- Current: Bipolar or unipolar 1 or 20 mA full scale or unipolar 4-20 mA
-- Excitation: +5 volt only; specify 3307A-E5
-- Resolution: 12 bits (0.025% of full scale)
-- Accuracy: ±0.15% (at 73.4º F), ±50 ppm/ºF
Analog Sampling
-- Sample rate: 1/sec to 1/8 hours for each channel
-- Sample interval: 1 s to 8 h, synchronized to the hour, channel independent
-- Values saved: Minimum, average and/or maximum per interval
-- Totalizers: 1 Gbyte totalizer per channel
Pulse/event Inputs
-- Type: Pulse counting or event recording, user selectable
-- Input: Uncommitted contact or active logic signals
-- Excitation: 10 µA contact sensing current; 5 volt pull-up
-- Contact bounce: 3 ms maximum, software programmable bounce filter
Pulse Totalizing:
-- Pulse rate: Low speed 100/s with bounce filter; Maximum pulses: 65,000 per interval; High speed: 20,000/s with no bounce filter
-- Totalizing interval: 1 s to 8 h, synchronized to the hour, channel independent
-- Values saved: Totals, overall and per interval
Event Sampling
-- Event rate: 1 event/s maximum
-- Values saved: Event with time stamp (in mm:dd:yy:hh:mm:ss format), and computed run time.
Alarms
-- Activation: Analog and event inputs only
-- Outputs: 2 Discrete outputs
-- Type: FET, open collector (open drain)
-- Maximum specifications: 30 VDC & 100 mA
-- Threshold: Software programmable threshold exceedance on analog channels (high, high-high, low, low-low); event activated on event channels
Alarm Logging
-- Trigger: Logging of analog channel triggered by inputs from analog or event channels
-- Pre-trigger buffer: 0 to 5 intervals
-- Post-trigger buffer: 0 to 50 intervals
Power
-- Battery type: 9-volt lithium battery pack with MTA connector
-- Battery life: 6 months @ 73.4º F, with 1 sample every 5 s on all channels, no modem
-- External DC: Regulated 12 VDC; Unregulated 15-35 VDC
Communication
-- Local RS-232 (standard); Opto-isolated; 300 to 19,200 baud via 9 pin D connector
-- Cellular: Internal Telog WM2/L1 cellular modem LTE Category 1 certified Verizon Wireless
-- Modem upgradable to future communications technologies
Mechanical & Environmental
-- Clock accuracy: ±0.01%
-- Operating temperature: -4 to 140º F
-- Enclosure: Bent aluminum panel mount assembly; size: 8.5"x6.8"x2.3"
-- Options: Fiberglass, IEC IP65 NEMA 4X enclosures
Support Software
-- Telog Online (Data Hosted Solution)
-- Telog Enterprise
-- Telogers for Windows
-- Trimble Unity
Recorder Model: Telog R-3314
Type: Multi-channel RTU (recording telemetry unit)
Recorder Channels
-- 6 Pulse/event channels
-- 8 Analog
Memory
-- Dynamically allocated among active channels: 512 Kbytes
--- Analog inputs only: 294,300 12-bit values
-- Pulse inputs only: 227,000 16-bit values
-- Event inputs only: 73,600 events
-- Storage: Wrap-around (first-in, first-out, FIFO) memory
Analog Inputs:
-- Type: Selectable using software
-- Voltage: Bipolar or unipolar 100 mV, 200 mV, 500 mV, 1, 2, 5, 10, or 20 V full scale, or unipolar 1 to 5 V
-- Current: Bipolar or unipolar 1 or 20 mA full scale or unipolar 4-20 mA
-- Resolution: 12 bits (0.025% of full scale)
-- Accuracy: ±0.15% (at 73.4º F), ±50 ppm/ºF
Analog Sampling
-- Sample rate: 1/sec to 1/8 hours for each channel
-- Sample interval: 1 s to 8 h, synchronized to the hour, channel independent
-- Values saved: Minimum, average and/or maximum per interval
-- Totalizers: 1 Gbyte totalizer per channel
Pulse/event Inputs
-- Type: Pulse counting or event recording, user selectable
-- Input: Uncommitted contact or active logic signals
-- Excitation: 10 µA contact sensing current; 5 volt pull-up
-- Contact bounce: 3 ms maximum, software programmable bounce filter
Pulse Totalizing:
-- Pulse rate: Low speed 100/s with bounce filter; Maximum pulses: 65,000 per interval; High speed: 20,000/s with no bounce filter
-- Totalizing interval: 1 s to 8 h, synchronized to the hour, channel independent
-- Values saved: Totals, overall and per interval
Event Sampling
-- Event rate: 1 event/s maximum
-- Values saved: Event with time stamp (in mm:dd:yy:hh:mm:ss format), and computed run time | Event with time stamp (in mm:dd:yy:hh:mm:ss format), and computed hi run time and lo run time
Alarms
-- Activation: Analog and event inputs only
-- Outputs: 4 Discrete outputs
-- Type: FET, open collector (open drain)
-- Maximum specifications: 30 VDC & 100 mA
-- Threshold: Software programmable threshold exceedance on analog channels (high, high-high, low, low-low); event activated on event channels
Alarm Logging
-- Trigger: Logging of analog channel triggered by inputs from analog or event channels
-- Pre-trigger buffer: 0 to 5 intervals
-- Post-trigger buffer: 0 to 50 intervals
Power
-- Battery type: 9-volt lithium battery pack with MTA connector
-- Battery life: 6 months @ 73.4º F, with 1 sample every 5 s on all channels, no modem
-- External DC: Regulated 12 VDC; Unregulated 15-35 VDC
Communication
-- Local RS-232 (standard); Opto-isolated; 300 to 19,200 baud via 9 pin D connector
-- Cellular: Internal Telog WM2/L1 cellular modem LTE Category 1 certified Verizon Wireless
-- Modem upgradable to future communications technologies
Mechanical & Environmental
-- Clock accuracy: ±0.01%
-- Operating temperature: -4 to 140º F
-- Enclosure: Bent aluminum panel mount assembly; size: 8.2"x9.9"x2.3"
-- Options: Fiberglass, IEC IP65 NEMA 4X enclosures
Support Software
-- Telog Online (Data Hosted Solution)
-- Telog Enterprise
-- Telogers for Windows
-- Trimble Unity
Recorder
Model: Telog R-3330
Type: Multi-channel recorder
Recorder Channels
-- 6 Pulse/event channels
-- 8 Analog
-- 16 Alarm/event
Memory
-- Dynamically allocated among active channels: 1024 Kbytes
--- Analog inputs only: 614,000 12-bit values
--- Pulse inputs only: 459,000 16-bit values
--- Event inputs only: 152,995 events
--- Storage: Wrap-around (first-in, first-out, FIFO) memory
Analog Inputs:
-- Type: Selectable using software
--- Voltage: Bipolar or unipolar 100 mV, 200 mV, 500 mV, 1, 2, 5, 10, or 20 V full scale, or unipolar 1 to 5 V
--- Current: Bipolar or unipolar 1 or 20 mA full scale or unipolar 4-20 mA
-- Resolution: 12 bits (0.025% of full scale)
-- Accuracy: ±0.15% (at 73.4º F), ±50 ppm/ºF
Analog Sampling
-- Sample rate: 1/sec to 1/8 hours for each channel
-- Sample interval: 1 s to 8 h, synchronized to the hour, channel independent
-- Values saved: Minimum, average and/or maximum per interval
-- Totalizers: 1 Gbyte totalizer per channel
Pulse/event Inputs
-- Type: Pulse counting or event recording, user selectable
-- Input: Uncommitted contact or active logic signals
-- Excitation: 10 µA contact sensing current; 5 volt pull-up
-- Contact bounce: 3 ms maximum, software programmable bounce filter
Pulse Totalizing:
-- Pulse rate: Low speed 100/s with bounce filter; Maximum pulses: 65,000 per interval; High speed: 20,000/s with no bounce filter
-- Totalizing interval: 1 s to 8 h, synchronized to the hour, channel independent
-- Values saved: Totals, overall and per interval
Event Sampling
-- Event rate: 1 event/s maximum
-- Values saved: Event with time stamp (in mm:dd:yy:hh:mm:ss format), and computed run time | Event with time stamp (in mm:dd:yy:hh:mm:ss format), and computed hi run time and lo run time
Alarm/Event Inputs
-- Type: Event recording only
-- Input: Uncommitted contact or active logic signals
-- Excitation: 10 µA contact sensing current; 5 volt pull-up
-- Contact bounce: 3 ms maximum, software programmable bounce filter
Alarms
-- Activation: Analog and event inputs only
-- Outputs: 2 Discrete outputs
-- Type: FET, open collector (open drain)
-- Maximum specifications: 30 VDC & 100 mA
-- Threshold: Software programmable threshold exceedance on analog channels (high, high-high, low, low-low); event activated on event channels
Power
-- Battery type: 9-volt lithium battery pack with MTA connector
-- Battery life: 4 months @ 73.4º F, with 1 sample every 5 s on all channels, no modem
-- External DC: Regulated 12 VDC; Unregulated 15-35 VDC
Communication
-- Local RS-232 (standard); Opto-isolated; 300 to 19,200 baud via 9 pin D connector
-- Cellular: Internal Telog WM2/L1 cellular modem LTE Category 1 certified Verizon Wireless
-- Modem upgradable to future communications technologies
Mechanical & Environmental
-- Clock accuracy: ±0.01%
-- Operating temperature: -4 to 140º F
-- Enclosure: Bent aluminum panel mount assembly; size: 8.2"x9.9"x2.3"
-- Options: Fiberglass, IEC IP65 NEMA 4X enclosures
Support Software
-- Telog Online (Data Hosted Solution)
-- Telog Enterprise
-- Telogers for Windows
-- Trimble Unity
Meters, Sensors, Options
Telog-supported Flowmeters
Flow meters via RS-232 or RS-485 interface to meter serial interface port:
- Hach Sigma series
- ISCO 2150 Laser & Signature Logger
- Marsh McBirney Flo-Dar & Flo Tote3
- Teledyne MGD ADFM & accQmin
- ADS Flowshark & Triton
- FloWav area velocity sensor
Telog-supplied Meters & Sensors
- Utrasonic sensor
- Pressure sensor
- Temperature sensor
- pH sensor
- Rain Gauge
Water Quality
- Hach Hydrolab multiparameter Sondes
- DataSonde 4a, MiniSonde 4a
- DSSX, DSS, MXX
- Hach WDM Pipe Sonde